1-800-968-2871
Schedule Service Today

 

1-800-968-2871
Contact Us
Let us know how we can help you and a Fire Pros representative will contact you within 24 hours.

Fire Pump Inspection, Repair & Installation in Michigan

For Fire Protection Services in Michigan, Call (800)968-2871!

Fire Pump Installation

A properly maintained fire pump is essential to the safety of a commercial building, providing the water necessary for optimal sprinkler operation. When a fire pump is working correctly, it helps to avoid injuries and fatalities during a fire while significantly reducing the damage at your facility. Regular inspection and maintenance are required to ensure a fire pump will operate properly during an emergency, and at Fire Pros, our experts have the skills and equipment to keep your fire pumps and sprinkler systems in NFPA-approved condition.
Contact Us

We serve businesses throughout Michigan, providing complete sales and service for fire pumps, sprinkler systems, fire suppression systems, alarm systems, and other fire protection equipment. With over 30 years of industry experience and convenient 24/7 emergency service, you can count on our team at Fire Pros for all your fire protection needs.

To have your fire pumps installed, inspected, and serviced in Michigan, call Fire Pros today at 800-968-2871 or contact us online.

Fire Pump Inspection & Maintenance in MI

Fire pumps do not often operate, making them more prone to damage from corrosion, seal failures, lubricant deterioration, and other factors than pumps that run regularly. Routine maintenance and inspections can help to prevent much of this damage and keep your fire pumps ready for an emergency. We offer complete inspection and maintenance services for fire pumps and related systems, and our process includes:

  • Evaluating – Our experts will evaluate the fire pump for signs of wear and damage, such as corrosion, cracked castings, leaking seals, loose fasteners, or damaged valves and fittings.
  • Checking couplings and shaft – Misaligned or damaged shafts and couplings could cause a pump to fail or a loss in performance. Our experts will check for proper alignment and operation.
  • Inspecting the circulation relief valve – A malfunctioning relief valve can cause the fire pump to overheat while operating in the shutoff condition, causing a pump failure or reducing its service life. Our team will inspect the valve for proper operation.
  • Lubricating bearings – Over time, lubricants can dry up or thin out, causing increased friction and possible pump failures. Our team will inspect the pump’s bearings and lubricate them if necessary.
  • Flow testing – Periodically, a fire pump should be tested at shutoff conditions to ensure it meets pressure and flow specifications at its minimum, rated, and peak loads. We can provide regular testing of your fire pump, plus annual testing of hose streams, flow meter systems, pump performance, and motor performance.

We service both electric and diesel fire pumps, and we offer a convenient, cost-effective inspection contract that can keep your fire pumps in working condition and up to code year-round.

Fire Pump Repair near Grand Rapids

When you have a problem with a fire pump at your Michigan business, you can count on our experts for reliable, quality fire pump repairs. Our experts have the equipment and experience to handle all common fire pump repairs, and we are available 24/7 for emergency service throughout Michigan, including Grand Rapids, Kalamazoo, Muskegon, and beyond.

Schedule Fire Pump Services in Michigan

Don’t take any chances. Keep your business, your employees, and your customers safe with complete fire pump services from our experts at Fire Pros.

FIRE PUMP SERVICES WE OFFER:

  • Diesel
  • Electric
  • Inspecting
  • Installation
  • Service & Repairs
  • On-site Training
  • Weekly, Monthly, Quarterly, and Annual Testing

If you are interested in our fire pump services, call our fire pump contractors Fire Pros is a dedicated fire protection company that works hard to keep buildings safe and fire code compliant.

Our fire protection company is based in Grand Rapids, Michigan, and offers services around Cadillac, Grayling, Holland, Kalamazoo, Lansing, Muskegon, Norton Shores, Portage, Roscommon, Saginaw, Traverse City, and Wyoming.

Contact us today at 800-968-2871 or visit us online to schedule a consultation! We service Grand Rapids, MI; Kalamazoo, MI; Detroit, MI; and the surrounding areas.

Contact Us
Let us know how we can help you
and a Fire Pros representative
will contact you within 24 hours.
Let’s TALK +
Click here
Hide Form -
Fire Pros Performs with ServiceTrade

Providing faster, smarter, and more efficient fire protection

Learn more here

Local Reviews

Fire Pros, LLC Rated 4.9 out of 5 stars based on 3670 customer reviews

Map of Ann Arbor, MI

Nice guys




Review of Fire Pros, LLC

Respectful and kind


Map of Troy, MI

Service manager




Review of Fire Pros, LLC


Map of Ann Arbor, MI

Another Portion of our Required Inspections




Review of Fire Pros, LLC

Staff was on time and friendly. Performed the work without incident and communicated well when they were finished.


Map of Bay City, MI

Great Service




Review of Fire Pros, LLC


Map of Dearborn, MI

Great Service




Review of Fire Pros, LLC

Professional and knowledgeable


Map of Detroit, MI

Fire Extinguisher Inspections




Review of Fire Pros, LLC

Professional and efficient.


Map of Dearborn, MI

Area Coach




Review of Fire Pros, LLC

Fantastic job! Great guys!


Map of Livonia, MI

Great Service, very polite and informative




Review of Fire Pros, LLC

Good experience, send again


Map of Bay City, MI

Building Manager




Review of Fire Pros, LLC

An excellent tech


Map of Grand Rapids, MI

No Problems




Review of Fire Pros, LLC


Excellent service




Review of Fire Pros, LLC

Great customer service. Excellent service.


Great Service, great technician




Review of Fire Pros, LLC

It was a pleasure to work with Sean!!!!!!!


Very good experience over the years.




Review of Fire Pros, LLC

Brandon Foote is very kind, patient, friendly and knowledgeable


Jared was very informative and updated me on all that needed to be done




Review of Fire Pros, LLC


Great service and Professionalism!




Review of Fire Pros, LLC

The technicians who came out, were very friendly, knowledgeable and helpful!


Dave was prompt in getting the inspection completed and docs over to me




Review of Fire Pros, LLC

i rec'd a call from Dave informing me the inspection was completed. He gave me a quick run down of the deficiencies. He had the inspection report in my emails before I could complete my notes on the file


New door magnet




Review of Fire Pros, LLC

Ron and Dennis were great as usual. Any problems they faced they overcame with professionalism. They did a great job.


Very helpful




Review of Fire Pros, LLC


Great service




Review of Fire Pros, LLC


Pastor




Review of Fire Pros, LLC


Mike R.

Mike R.

NAC 1 BOOSTER PANEL BY FACP: Batteries in NAC 1 panel are due for replacement due to age. They are (2) 12V 7AH batteries. - repair

Near W Grand River Ave, Williamston, MI 48895
Mark S.

Mark S.

Near Dobry Dr, Sterling Heights, MI 48314
William S.

William S.

Wet: Perform a 5-year internal assessment of system piping that is due. If an obstruction is present, this can render the sprinkler system not properly operate in the case of a fire. NFPA 25 (14.2.1.1) An assessment of the internal condition of piping shall be conducted at a minimum of every 5 years or in accordance with 14.2.1.2 to inspect for the presence of foreign organic and inorganic material. Wet: Perform a 5-year internal inspection of the Fire Department Connection (FDC) check valve. Check is in the basement, next to the bathroom, up in the floor joist. NFPA 25 (13.4.2.1) Check valves shall be inspected internally every 5 years to verify that all components operate correctly, move freely, and are in good condition. Wet: Add the missing spare sprinkler heads in the spare headbox. NFPA 25 (5.4.1.5.4) The stock of spare sprinklers shall include all types and ratings installed and shall be as follows; Facilities having 300-1000 sprinklers – minimum of 12 spare sprinklers

Near Front Ave NW, Grand Rapids, MI 49504
Tyler H.

Tyler H.

Mike Price just called- said the panel has been beeping since we left.

Near Danvers Ct SE, Kentwood, MI 49512
Mike R.

Mike R.

Heat Detectors above Reception Desk and in Directors office are not tied into system and require removal or repair. Areas are currently covered by smoke detectors. - repair Heat Detectors throughout (4) require replacement due to age/condition. Detectors reflect Manf Dates from 1983 to 1999 4 - System Sensor 135 degree fixed / ROR detectors - repair Phone line 1 has voltage, no dial. Phone line 2 has heavy static on line. Phone lines are in disrepair and have been a continuing issue per the Director. Recommend installation of Cellular Communicator at location. - repair This quote is for the repairs and to add cellular communication to the fire alarm panel .

Near N Lilley Rd, Canton, MI 48187
David H.

David H.

Near Thomas Rd, Ann Arbor, MI 48108
Alex H.

Alex H.

Near Dequindre Rd, Madison Heights, MI 48071
Art L.

Art L.

Portable Extinguishers Inspection

Near E Paris Ave SE, Grand Rapids, MI 49546
Tyler H.

Tyler H.

Annual Fire Alarm Inspection Edwards fire alarm panel, 3 booster panels, 15 initiating devices, 25 indicating devices

Near Brown St SE, Grand Rapids, MI 49507
Robert G.

Robert G.

Near Smith Rd, Fowlerville, MI 48836
Jared J.

Jared J.

Portable Extinguishers and Fire Hose Inspection

Near Farmington Rd, Farmington Hills, MI 48334
George S.

George S.

Near E Scripps Rd, Orion charter Township, MI 48360
Brandon  F.

Brandon F.

Completed puff test and relocated pull station per fire Marshall request.

Near E Grand River Rd, East Lansing, MI 48823
William S.

William S.

Wet Stairwell next to Community Room B Riser: Remove and replace the outdated gauge. NFPA 25 (13.2.7.2) Gauges shall be replaced every 5 years Wet Stairwell next to Community Room B Riser: Perform a 5-year internal assessment of system piping that is due. If an obstruction is present, this can render the sprinkler system not properly operate in the case of a fire (8' ladder needed). NFPA 25 (14.2.1.1) An assessment of the internal condition of piping shall be conducted at a minimum of every 5 years or in accordance with 14.2.1.2 to inspect for the presence of foreign organic and inorganic material. Wet Stairwell next to Community Room B Riser: Perform a 5-year internal inspection of the Fire Department Connection (FDC) check valve. NFPA 25 (13.4.2.1) Check valves shall be inspected internally every 5 years to verify that all components operate correctly, move freely, and are in good condition.

Near Jupiter Ave NE, Plainfield charter Township, MI 49306
Art L.

Art L.

Industrial/Dry Chemical Suppression Repair

Near 29th St SE, Grand Rapids, MI 49512
Sean W.

Sean W.

Near Health Dr SW, Wyoming, MI 49519
John  R.

John R.

Near Wiersma St NE, Cedar Springs, MI 49319
Art L.

Art L.

Portable Extinguishers Inspection

Near W Main St, Lowell, MI 49331
Mark S.

Mark S.

Near N Dawson St, Sandusky, MI 48471
George S.

George S.

Near Giddings Rd, Orion charter Township, MI 48359
David H.

David H.

Near Washtenaw Ave, Ann Arbor, MI 48104
Art L.

Art L.

Emergency / Exit Lights and Portable Extinguishers Inspection

Near 44th St SE, Kentwood, MI 49512
John  R.

John R.

Near Griswold St, Hart, MI 49420
Sean W.

Sean W.

Near Central Blvd, Hudsonville, MI 49426
Mark S.

Mark S.

Near N Dawson St, Sandusky, MI 48471