Comstock Park
Local Reviews
for Comstock Park, MI
great service
Julie - Comstock Park, MI 49321
Awesome service!
Lisa - Comstock Park, MI 49321
The tech was very knowledgeable and helpful. Thanks!
Great service
Diane - Comstock Park, MI 49321
Very good service.
Curtis - Comstock Park, MI 49321
Inspection
Tate - Comstock Park, MI 49321
Brandon came into today do inspect our equipment today and was great and very friendly.
Great guy great service
Dan - Comstock Park, MI 49321
Perfect!
Great Job!
Lisa - Comstock Park, MI 49321
Sean did a great job.
Great service
Stephanie - Comstock Park, MI 49321
Great service
Shelly - Comstock Park, MI 49321
Fantastic Service!
ET - Comstock Park, MI 49321
Everyone is friendly and easy to work with. They are great with fully explaining the scope of work and the reasoning behind the services they perform.
Response from Fire Pros | Fire Systems of MI | Adam's Fire :
Thank you for leaving a review, we greatly appreciate your feedback! Ryan is an awesome asset and we want to create value for you and your organization, Thanks again and have a fire safe day! Also if you have time, please visit Google and leave us a review there as well, we would greatly appreciate it!
Wonderful Service
Karen - Comstock Park, MI 49321
Work was done and explained professionally; nice personality and proficient.
Very freindly crew
Josh - Comstock Park, MI 49321
Always easy dealing with the Fire Pros crew
The Fire Pro's team is always nice to work with
Josh - Comstock Park, MI 49321
great service
Dennis - Comstock Park, MI 49321
Excellent service
Josh - Comstock Park, MI 49321
The techs are always nice and professional
Review
Drew - Comstock Park, MI 49321
Feeling safe
Annette - Comstock Park, MI 49321
The gentlemen that conducted the inspection and service were professional and personable. They also had suggestions that were helpful to overall safety for the plant. Thank you!
The service technician was phenomenal!
Jeff - Comstock Park, MI 49321
Mike R.
Gary B.
Inoperable Deficiency for ANSUL R-102 3g + 1.5g Kitchen: Number of Systems failed : 1. Initial inspection of system uncovered NUMEROUS deficiencies: **NO audio/visual notification **3g & 1.5g cylinders are red and NEVER tested- Need to replace with (2) 3g SS to cover added flows. **NO electrical shutdown— Need electrician **system did NOT activate from terminal link— new link line **Need to T appliance piping and install another nozzle over 6-burner **290 over 48” griddle needs to be 260 **Need to add link brackets over (2) fryers, 48” griddle, and (1) over 6-burner range **System due for regulator and hose testing ** No access to gas valve due to location and piping above drop ceiling. Could NOT test ** New R-102 Double tank cartridge New link line: (8) link line bracket kits, (20’) conduit, (7) 360F links, (1) 500F link, (8) scissor brackets, and (5) corner pulleys. New 260 nozzle for griddle Chrome T, (1) 10”nipple, (1) 2” nipple, 12” chrome sleeve, and 260 nozzle for 6-
Sean W.
Sean W.
John R.
John R.
Eduardo A.
John R.
William S.
Sprinkler Service Call
Mike R.
Perform Alarm inspection: approx 20 devices
William S.
Sprinkler Service Call
William S.
Obstruction Investigation and Sprinkler Repair
Brandon F.
Completed kitchen suppression system inspection
Brandon F.
Completed kitchen suppression system inspection
Brandon F.
Completed (2) kitchen suppression system inspections.
Brandon F.
Completed quoted job
Eduardo A.
Tyler H.
Nathan called- (517-914-5441) EPS called him, fire panel is showing NAC 1 & 2 tbl- needs svc to check - call him when on the way- he needs to get you in the bldg.