Fire Pros is a one-stop shop providing comprehensive fire protection services in Roscommon and the surrounding areas of Roscommon County. Our teams are skilled and experienced as well as highly adept at customizing our services to meet the unique needs of each client.

Contact Fire Pros online to schedule fire protection services, or call (800)968-2871 to connect with a service specialist now!

Fire Sprinkler Systems in Roscommon

Fire sprinkler systems form a sturdy foundation for any fire protection system, offering an automatic 24-hour response in the event of a fire emergency. The experts at Fire Pros have been designing, installing, and maintaining fire sprinkler systems for commercial and industrial clients for years.

For Roscommon fire sprinkler services, trust Fire Pros. We offer:

Crawford County Fire Alarm Systems

Alarms are critical for notifying everyone on the premises of a fire, allowing for as much time as possible to get to safety. Fire Pros provides comprehensive 24/7 alarm monitoring in addition to design and installation services.

Roscommon fire alarm system services from Fire Pros include:

  • Annual and periodic fire alarm inspections
  • Fire alarm repair
  • 24-hour emergency support
  • Fire alarm installation
  • 24-hour fire alarm monitoring

Fire Extinguisher Inspection, Installation, Repair & Recharge

Properly placed extinguishers can mean the difference between getting out safely and being blocked from a pathway to the designated exits. Fire Pros will assist you in choosing the correct extinguishers to suit your needs, and our support services can ensure your business is fully NFPA- and local code-compliant.

We provide these fire extinguisher services in Roscommon, MI:

Emergency Lighting

Keeping panic to a minimum and offering easy to follow emergency paths for exiting your building can make all the difference during a fire. Our emergency lighting and exit light services are ideal for abating chaos and maintaining order during evacuations from your Roscommon business.

Our exit and emergency lighting services in Roscommon, include:

  • Exit and emergency lighting inspections
  • Exit and emergency lighting repair
  • Exit and emergency lighting maintenance
  • Exit and emergency lighting installation

Commercial Kitchen Hood Suppression

Kitchen fires are notoriously violent and quick to spread. Even worse, many standard forms of fire suppression simply do not work against a grease or oil fire. Fire Pros can outfit your restaurant or commercial kitchen with a superior solution using our special hazard and kitchen hood suppression systems.

Schedule these kitchen hood suppression services with Fire Pros:

Complete Fire Protection Services in Roscommon, Michigan

Fire Pros is dedicated to offering your business a superior fire protection solution through the use of top-class products and technology, as well as tailored customer service. Whether you need full installation services, or routine periodic fire protection maintenance, connect with Fire Pros in Roscommon.

Call (800)968-2871 or contact Fire Pros online to outfit your Roscommon commercial business with top-notch fire protection systems!

 

Contact Us
Let us know how we can help you
and a Fire Pros representative
will contact you within 24 hours.
Let’s TALK +
Click here
Hide Form -
Fire Pros Performs with ServiceTrade

Providing faster, smarter, and more efficient fire protection

Learn more here

Local Reviews

Fire Pros, LLC Rated 4.9 out of 5 stars based on 3670 customer reviews

Map of Ann Arbor, MI

Nice guys




Review of Fire Pros, LLC

Respectful and kind


Map of Troy, MI

Service manager




Review of Fire Pros, LLC


Map of Ann Arbor, MI

Another Portion of our Required Inspections




Review of Fire Pros, LLC

Staff was on time and friendly. Performed the work without incident and communicated well when they were finished.


Map of Bay City, MI

Great Service




Review of Fire Pros, LLC


Map of Dearborn, MI

Great Service




Review of Fire Pros, LLC

Professional and knowledgeable


Map of Detroit, MI

Fire Extinguisher Inspections




Review of Fire Pros, LLC

Professional and efficient.


Map of Dearborn, MI

Area Coach




Review of Fire Pros, LLC

Fantastic job! Great guys!


Map of Livonia, MI

Great Service, very polite and informative




Review of Fire Pros, LLC

Good experience, send again


Map of Bay City, MI

Building Manager




Review of Fire Pros, LLC

An excellent tech


Map of Grand Rapids, MI

No Problems




Review of Fire Pros, LLC


Excellent service




Review of Fire Pros, LLC

Great customer service. Excellent service.


Great Service, great technician




Review of Fire Pros, LLC

It was a pleasure to work with Sean!!!!!!!


Very good experience over the years.




Review of Fire Pros, LLC

Brandon Foote is very kind, patient, friendly and knowledgeable


Jared was very informative and updated me on all that needed to be done




Review of Fire Pros, LLC


Great service and Professionalism!




Review of Fire Pros, LLC

The technicians who came out, were very friendly, knowledgeable and helpful!


Dave was prompt in getting the inspection completed and docs over to me




Review of Fire Pros, LLC

i rec'd a call from Dave informing me the inspection was completed. He gave me a quick run down of the deficiencies. He had the inspection report in my emails before I could complete my notes on the file


New door magnet




Review of Fire Pros, LLC

Ron and Dennis were great as usual. Any problems they faced they overcame with professionalism. They did a great job.


Very helpful




Review of Fire Pros, LLC


Great service




Review of Fire Pros, LLC


Pastor




Review of Fire Pros, LLC


Mike R.

Mike R.

NAC 1 BOOSTER PANEL BY FACP: Batteries in NAC 1 panel are due for replacement due to age. They are (2) 12V 7AH batteries. - repair

Near W Grand River Ave, Williamston, MI 48895
Mark S.

Mark S.

Near Dobry Dr, Sterling Heights, MI 48314
William S.

William S.

Wet: Perform a 5-year internal assessment of system piping that is due. If an obstruction is present, this can render the sprinkler system not properly operate in the case of a fire. NFPA 25 (14.2.1.1) An assessment of the internal condition of piping shall be conducted at a minimum of every 5 years or in accordance with 14.2.1.2 to inspect for the presence of foreign organic and inorganic material. Wet: Perform a 5-year internal inspection of the Fire Department Connection (FDC) check valve. Check is in the basement, next to the bathroom, up in the floor joist. NFPA 25 (13.4.2.1) Check valves shall be inspected internally every 5 years to verify that all components operate correctly, move freely, and are in good condition. Wet: Add the missing spare sprinkler heads in the spare headbox. NFPA 25 (5.4.1.5.4) The stock of spare sprinklers shall include all types and ratings installed and shall be as follows; Facilities having 300-1000 sprinklers – minimum of 12 spare sprinklers

Near Front Ave NW, Grand Rapids, MI 49504
Tyler H.

Tyler H.

Mike Price just called- said the panel has been beeping since we left.

Near Danvers Ct SE, Kentwood, MI 49512
Mike R.

Mike R.

Heat Detectors above Reception Desk and in Directors office are not tied into system and require removal or repair. Areas are currently covered by smoke detectors. - repair Heat Detectors throughout (4) require replacement due to age/condition. Detectors reflect Manf Dates from 1983 to 1999 4 - System Sensor 135 degree fixed / ROR detectors - repair Phone line 1 has voltage, no dial. Phone line 2 has heavy static on line. Phone lines are in disrepair and have been a continuing issue per the Director. Recommend installation of Cellular Communicator at location. - repair This quote is for the repairs and to add cellular communication to the fire alarm panel .

Near N Lilley Rd, Canton, MI 48187
David H.

David H.

Near Thomas Rd, Ann Arbor, MI 48108
Alex H.

Alex H.

Near Dequindre Rd, Madison Heights, MI 48071
Art L.

Art L.

Portable Extinguishers Inspection

Near E Paris Ave SE, Grand Rapids, MI 49546
Tyler H.

Tyler H.

Annual Fire Alarm Inspection Edwards fire alarm panel, 3 booster panels, 15 initiating devices, 25 indicating devices

Near Brown St SE, Grand Rapids, MI 49507
Robert G.

Robert G.

Near Smith Rd, Fowlerville, MI 48836
Jared J.

Jared J.

Portable Extinguishers and Fire Hose Inspection

Near Farmington Rd, Farmington Hills, MI 48334
George S.

George S.

Near E Scripps Rd, Orion charter Township, MI 48360
Brandon  F.

Brandon F.

Completed puff test and relocated pull station per fire Marshall request.

Near E Grand River Rd, East Lansing, MI 48823
William S.

William S.

Wet Stairwell next to Community Room B Riser: Remove and replace the outdated gauge. NFPA 25 (13.2.7.2) Gauges shall be replaced every 5 years Wet Stairwell next to Community Room B Riser: Perform a 5-year internal assessment of system piping that is due. If an obstruction is present, this can render the sprinkler system not properly operate in the case of a fire (8' ladder needed). NFPA 25 (14.2.1.1) An assessment of the internal condition of piping shall be conducted at a minimum of every 5 years or in accordance with 14.2.1.2 to inspect for the presence of foreign organic and inorganic material. Wet Stairwell next to Community Room B Riser: Perform a 5-year internal inspection of the Fire Department Connection (FDC) check valve. NFPA 25 (13.4.2.1) Check valves shall be inspected internally every 5 years to verify that all components operate correctly, move freely, and are in good condition.

Near Jupiter Ave NE, Plainfield charter Township, MI 49306
Art L.

Art L.

Industrial/Dry Chemical Suppression Repair

Near 29th St SE, Grand Rapids, MI 49512
Sean W.

Sean W.

Near Health Dr SW, Wyoming, MI 49519
John  R.

John R.

Near Wiersma St NE, Cedar Springs, MI 49319
Art L.

Art L.

Portable Extinguishers Inspection

Near W Main St, Lowell, MI 49331
Mark S.

Mark S.

Near N Dawson St, Sandusky, MI 48471
George S.

George S.

Near Giddings Rd, Orion charter Township, MI 48359
David H.

David H.

Near Washtenaw Ave, Ann Arbor, MI 48104
Art L.

Art L.

Emergency / Exit Lights and Portable Extinguishers Inspection

Near 44th St SE, Kentwood, MI 49512
John  R.

John R.

Near Griswold St, Hart, MI 49420
Sean W.

Sean W.

Near Central Blvd, Hudsonville, MI 49426
Mark S.

Mark S.

Near N Dawson St, Sandusky, MI 48471