1-800-968-2871
Schedule Service Today

 

1-800-968-2871
Contact Us
Let us know how we can help you and a Fire Pros representative will contact you within 24 hours.

Fire Protection Services in Holland, Michigan

Fire Sprinkler Systems, Fire Alarms, Fire Extinguishers & More

As a leading fire protection company in Holland and Macomb County, Fire Pros has been offering superior products and services for over 30 years. We know very well all of the dangers that a fire can pose to your business, so we offer comprehensive plans and systems designed to keep you and your clients safe.

When seeking fire protection in Holland call (800)968-2871 or contact Fire Pros on the web!

Fire Sprinkler Systems in Holland

Sprinklers are the ideal suppression system for small to medium-sized fires and can help to prevent fire damage and property loss. For around the clock protection you’ll find no better solution, and you can count on Fire Pros for complete installation, maintenance, and repair.

Reach out to our Holland fire sprinkler system experts for:

Fire Alarm Systems in Holland, MI

Time is a resource you can’t afford to waste when it comes to a fire. A properly integrated alarm system can protect the health and lives of clients and employees, and helps your business to get into contact with firefighters before things get out of hand. We offer leading products from trusted names like Honeywell and Potter, among others.

Fire Pros provides full fire alarm system services, including:

Call (800)968-2871 or contact Fire Pros online to request fire protection services in Holland.

Holland, MI Fire Extinguisher Services

When it comes to fire extinguishers you have to choose the correct type, and all employees and associates should be trained in their use. Fire Pros can help you select the right options to meet your needs, and offers extensive hands-on training.

Fire Pros of Holland offers fire extinguisher services that include:

Exit & Emergency Lighting for Your Business in Holland

Adequately lit escape routes and exits are imperative for cutting down on the disorder that a fire emergency can cause. Our team can design and install effective lighting systems, including emergency lights that will activate when normal lighting fails.

For exit and emergency lighting services, you can rely on Fire Pros. Contact us for:

  • Exit and emergency lighting inspections
  • Exit and emergency lighting repair
  • Exit and emergency lighting maintenance
  • Exit and emergency lighting installation

Commercial Kitchen Fire Protection in Macomb County

Kitchens are one of the primary sources of a fire emergency, and yours should be equipped and prepared to handle them. Fire Pros can assist, and our certified fire protection professionals are highly adept at finding what works best for you.

We offer kitchen hood suppression services in Holland, including:

Reach Fire Pros When You Need Fire Protection Services in Holland, MI

Fire Pros is your partner in keeping your business and clients safe. We are dedicated to offering quality, dependable products and our full range of support services to all businesses in Holland, Michigan.

Contact Fire Pros to begin planning your fire protection systems in Holland!

Contact Us
Let us know how we can help you
and a Fire Pros representative
will contact you within 24 hours.
Let’s TALK +
Click here
Hide Form -
Fire Pros Performs with ServiceTrade

Providing faster, smarter, and more efficient fire protection

Learn more here

Local Reviews

Fire Pros, LLC Rated 4.9 out of 5 stars based on 3670 customer reviews

Map of Ann Arbor, MI

Nice guys




Review of Fire Pros, LLC

Respectful and kind


Map of Troy, MI

Service manager




Review of Fire Pros, LLC


Map of Ann Arbor, MI

Another Portion of our Required Inspections




Review of Fire Pros, LLC

Staff was on time and friendly. Performed the work without incident and communicated well when they were finished.


Map of Bay City, MI

Great Service




Review of Fire Pros, LLC


Map of Dearborn, MI

Great Service




Review of Fire Pros, LLC

Professional and knowledgeable


Map of Detroit, MI

Fire Extinguisher Inspections




Review of Fire Pros, LLC

Professional and efficient.


Map of Dearborn, MI

Area Coach




Review of Fire Pros, LLC

Fantastic job! Great guys!


Map of Livonia, MI

Great Service, very polite and informative




Review of Fire Pros, LLC

Good experience, send again


Map of Bay City, MI

Building Manager




Review of Fire Pros, LLC

An excellent tech


Map of Grand Rapids, MI

No Problems




Review of Fire Pros, LLC


Excellent service




Review of Fire Pros, LLC

Great customer service. Excellent service.


Great Service, great technician




Review of Fire Pros, LLC

It was a pleasure to work with Sean!!!!!!!


Very good experience over the years.




Review of Fire Pros, LLC

Brandon Foote is very kind, patient, friendly and knowledgeable


Jared was very informative and updated me on all that needed to be done




Review of Fire Pros, LLC


Great service and Professionalism!




Review of Fire Pros, LLC

The technicians who came out, were very friendly, knowledgeable and helpful!


Dave was prompt in getting the inspection completed and docs over to me




Review of Fire Pros, LLC

i rec'd a call from Dave informing me the inspection was completed. He gave me a quick run down of the deficiencies. He had the inspection report in my emails before I could complete my notes on the file


New door magnet




Review of Fire Pros, LLC

Ron and Dennis were great as usual. Any problems they faced they overcame with professionalism. They did a great job.


Very helpful




Review of Fire Pros, LLC


Great service




Review of Fire Pros, LLC


Pastor




Review of Fire Pros, LLC


Mike R.

Mike R.

NAC 1 BOOSTER PANEL BY FACP: Batteries in NAC 1 panel are due for replacement due to age. They are (2) 12V 7AH batteries. - repair

Near W Grand River Ave, Williamston, MI 48895
Mark S.

Mark S.

Near Dobry Dr, Sterling Heights, MI 48314
William S.

William S.

Wet: Perform a 5-year internal assessment of system piping that is due. If an obstruction is present, this can render the sprinkler system not properly operate in the case of a fire. NFPA 25 (14.2.1.1) An assessment of the internal condition of piping shall be conducted at a minimum of every 5 years or in accordance with 14.2.1.2 to inspect for the presence of foreign organic and inorganic material. Wet: Perform a 5-year internal inspection of the Fire Department Connection (FDC) check valve. Check is in the basement, next to the bathroom, up in the floor joist. NFPA 25 (13.4.2.1) Check valves shall be inspected internally every 5 years to verify that all components operate correctly, move freely, and are in good condition. Wet: Add the missing spare sprinkler heads in the spare headbox. NFPA 25 (5.4.1.5.4) The stock of spare sprinklers shall include all types and ratings installed and shall be as follows; Facilities having 300-1000 sprinklers – minimum of 12 spare sprinklers

Near Front Ave NW, Grand Rapids, MI 49504
Tyler H.

Tyler H.

Mike Price just called- said the panel has been beeping since we left.

Near Danvers Ct SE, Kentwood, MI 49512
Mike R.

Mike R.

Heat Detectors above Reception Desk and in Directors office are not tied into system and require removal or repair. Areas are currently covered by smoke detectors. - repair Heat Detectors throughout (4) require replacement due to age/condition. Detectors reflect Manf Dates from 1983 to 1999 4 - System Sensor 135 degree fixed / ROR detectors - repair Phone line 1 has voltage, no dial. Phone line 2 has heavy static on line. Phone lines are in disrepair and have been a continuing issue per the Director. Recommend installation of Cellular Communicator at location. - repair This quote is for the repairs and to add cellular communication to the fire alarm panel .

Near N Lilley Rd, Canton, MI 48187
David H.

David H.

Near Thomas Rd, Ann Arbor, MI 48108
Alex H.

Alex H.

Near Dequindre Rd, Madison Heights, MI 48071
Art L.

Art L.

Portable Extinguishers Inspection

Near E Paris Ave SE, Grand Rapids, MI 49546
Tyler H.

Tyler H.

Annual Fire Alarm Inspection Edwards fire alarm panel, 3 booster panels, 15 initiating devices, 25 indicating devices

Near Brown St SE, Grand Rapids, MI 49507
Robert G.

Robert G.

Near Smith Rd, Fowlerville, MI 48836
Jared J.

Jared J.

Portable Extinguishers and Fire Hose Inspection

Near Farmington Rd, Farmington Hills, MI 48334
George S.

George S.

Near E Scripps Rd, Orion charter Township, MI 48360
Brandon  F.

Brandon F.

Completed puff test and relocated pull station per fire Marshall request.

Near E Grand River Rd, East Lansing, MI 48823
William S.

William S.

Wet Stairwell next to Community Room B Riser: Remove and replace the outdated gauge. NFPA 25 (13.2.7.2) Gauges shall be replaced every 5 years Wet Stairwell next to Community Room B Riser: Perform a 5-year internal assessment of system piping that is due. If an obstruction is present, this can render the sprinkler system not properly operate in the case of a fire (8' ladder needed). NFPA 25 (14.2.1.1) An assessment of the internal condition of piping shall be conducted at a minimum of every 5 years or in accordance with 14.2.1.2 to inspect for the presence of foreign organic and inorganic material. Wet Stairwell next to Community Room B Riser: Perform a 5-year internal inspection of the Fire Department Connection (FDC) check valve. NFPA 25 (13.4.2.1) Check valves shall be inspected internally every 5 years to verify that all components operate correctly, move freely, and are in good condition.

Near Jupiter Ave NE, Plainfield charter Township, MI 49306
Art L.

Art L.

Industrial/Dry Chemical Suppression Repair

Near 29th St SE, Grand Rapids, MI 49512
Sean W.

Sean W.

Near Health Dr SW, Wyoming, MI 49519
John  R.

John R.

Near Wiersma St NE, Cedar Springs, MI 49319
Art L.

Art L.

Portable Extinguishers Inspection

Near W Main St, Lowell, MI 49331
Mark S.

Mark S.

Near N Dawson St, Sandusky, MI 48471
George S.

George S.

Near Giddings Rd, Orion charter Township, MI 48359
David H.

David H.

Near Washtenaw Ave, Ann Arbor, MI 48104
Art L.

Art L.

Emergency / Exit Lights and Portable Extinguishers Inspection

Near 44th St SE, Kentwood, MI 49512
John  R.

John R.

Near Griswold St, Hart, MI 49420
Sean W.

Sean W.

Near Central Blvd, Hudsonville, MI 49426
Mark S.

Mark S.

Near N Dawson St, Sandusky, MI 48471